Fluid Level Sensors

Standex Electronics custom and standard reed switch based fluid level sensors are available in a variety of configurations for a multitude of applications. Standex LS100, 200 and 300 series conductivity based fluid level sensors are a comprehensive line of fluid level sensors that can be applied in most any application where conductivity based sensors are appropriate. From the bare bones LS100 series sensors, which must be driven from external electronics to the turn key LS300 series sensors that have a switched output, Standex sensors are engineered as needed to meet customer requirements.

  • Reed switch based fluid level sensors are used in a large variety of liquid level applications
  • LS200 and 300 series sensors are equipped with a Standex patented bias ring, designed to eliminate the issues of sensitivity changes that can occur due to a buildup of conductive material around the sensor which can cause substantial shifts in sensor sensitivity. The Standex bias ring is charged with an opposing electrical polarity and eliminates secondary conductive paths, which can cause false full indications.
  • Typical LS applications include monitoring of soap levels in clothes washers and sensing food syrup levels in dispensing equipment
  • LS sensors may be used for basement flood water or the backup of fixed or mobile septic systems due to the ability of this technology to operate in conductive fluids with high particulate matter and large amounts of residue
  • Reed switch or LS sensors may be used for automotive applications for monitoring windshield washer fluid and coolant levels.
  • Standex sensors can be mounted with a seal grommet, spin welded or hot plate bonded onto plastic containers, or screw threaded to the container
  • Standex conductivity sensors may be operated by a DC Voltage, DC Current or user electronics.

Sensors Catalog

Download load the entire Standex Electronics catalog of fluid level and proximity sensors

R12431 Series

  • For blow or injection molded bottles
  • Side mount design uses separate seal grommet
  • Form A (normally open) and Form B (normally closed) operation
  • Switch rated 0.5A/100V/10VA max
  • Internal snubber resistor
  • Connector meets requirements of Packard part number12162289
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12431 Series

R12449 Series

  • For blow or injection molded bottles
  • Side mount design uses separate seal grommet
  • Form A (normally open) and Form B (normally closed) operation
  • Switch rated 0.5A/100V/10VA max
  • Internal snubber resistor
  • Mates with Toyota connector P/N 90980-11068
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12449 Series

R12456 Series

  • For blow or injection molded bottles
  • Side mount design uses separate seal grommet
  • Form A (normally open) and Form B (normally closed) operation
  • Switch rated 0.5A/100V/10VA max
  • Internal snubber resistor
  • Mates with Yazaki 7283-6434-40
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12456 Series

R12347 Series

  • For blow or injection molded bottles
  • Bottom mount design
  • Form A (normally open) and Form B (normally closed) operation
  • Switch rated 0.5A/100V/10VA max
  • Internal snubber resistor
  • Mates with Ford E57B14A464AA
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12347 Series

R12349 Series

  • For blow or injection molded bottles
  • Side mount design
  • Form A (normally open) and Form B (normally closed) operation
  • Switch rated 0.5A/100V/10VA max
  • Internal snubber resistor
  • Mates with Ford E57B14A464AA
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12349 Series

R12072 Series

  • For blow or injection molded bottles
  • Top mount/ snap in design
  • Form A (normally open) operation
  • Switch rated 1.5A/200V/50VA max
  • Adjustable sensing point up to 18 inches from top of bottle
  • Standard termination-0.25 inch open spade
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12072 Series

R12372 Series

  • For blow or injection molded bottles
  • Indication delay feature
  • Bottom mount design uses separate seal grommet
  • Form A (normally open) and Form B (normally closed) operation
  • Switch rated 1.5A/200V/50VA max
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12372 Series

R12421 Series

  • For blow or injection molded bottles
  • Indication delay feature
  • Bottom mount design uses separate seal grommet
  • Form A (normally open) and Form B (normally closed) operation
  • Switch rated 1.5A/200V/50VA max
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12421 Series

R12406 Series

  • For blow or injection molded bottles
  • Indication delay feature
  • Bottom mount design with power harness
  • Form A (normally open) and Form B (normally
  • closed) operation
  • Switch rated 1.5A/200V/50VA max
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12406 Series

LS100 Series

  • Passive device with no internal electronics
  • Driven from external electronics
  • Suitable for most conductive fluids with minimal particulate matter
  • May be operated from user?s electronics in a ?pulsing? mode to reduce electrolysis
  • May be operated with a bipolar pulsing current from user electronics, eliminating electrolysis
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
LS100 Series

LS200 Series

  • False Full Protection and current level shift to indicate fluid level
  • Available as a two-wire device
  • Capable of substantial miniaturization
  • Equipped with Standex patented ?bias ring? concept
  • Suitable for most conductive fluids
  • Suitable in fluids with substantial particulate matter
  • Operated by a DC current pulse supplied from user?s electronics; current draw indicates fluid level
  • Optional LED available for local fluid level indication
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
LS200 Series

LS300 Series

  • Sensitivity Shift / False Full Protection
  • Full electronics and substantial probe miniaturization
  • Equipped with Standex patented ?bias ring? concept
  • Available as a three-wire device
  • Suitable for most conductive fluids
  • Suitable in fluids with substantial particulate matter
  • Internal electronics used to eliminate electrolysis
  • Input is 9V to 30 V DC
  • Provided with a switched output; 30 volt open collector sync, TTL or CMOS
  • Optional LED available for local fluid level indication
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
LS300 Series

R12468 Series

  • External sensor for injection molded bottles
  • Form A or Form B operation with separate float
  • Bottom mount with o-ring seal
  • Switch rated 1.5A /200V/50VA max
  • Mates with Packard P/N 12052641
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12468 Series

B12469 Series

  • Float / magnet assembly operates with R12468 sensor assembly
  • Float locates in the bottle assembly
  • Foamed Polypropylene Plastic
  • Specific gravity per application
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
B12469 Series

R12481 Series

  • External sensor for injection molded bottles
  • Form A or Form B operation with separate float
  • Bottom mount with o-ring seal
  • Switch rated 0.5A/100V/10VA max
  • Mates with Packard P/N 12052641
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12481 Series

B12482 Series

  • Float / magnet assembly operates with R12481 sensor assembly
  • Float locates in bottle assembly
  • Foamed Polypropylene Plastic
  • Specific gravity per application
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
B12482 Series

R11774 Series

  • External sensor for injection molded bottles
  • Form A (normally open) operation with
  • separate float
  • Switch rated 0.5A/100V/10VA max
  • Snap lock mounting
  • Integral connector
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R11774 Series

R12180 Series

  • External sensor for injection molded bottles
  • Form A (normally open) operation with
  • separate float
  • Switch rated 0.5A/100V/10VA max
  • Snap lock mounting
  • Integral connector
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
R12180 Series

B12450 Series Float

  • Float / magnet assembly operates with
  • R11774 and R12180 series sensors
  • Float locates in bottle assembly
  • Foamed PP
  • Operates with fluid SG at 0.79 min
  • Contact Standex Electronics for more information on this or to discuss your specific requirement
B12450 Series Float

© Standex Electronics, Inc.   All Rights Reserved.